Aleta.hr

Details

  • Earthing, lightning and surge protection
  • Combined arrester for power supply systems
  • 1 KOM
  • OBO

Technical specifications

System configuration DC

Yes

System configuration IT

No

System configuration TN

No

System configuration TN-C

No

System configuration TN-C-S

No

System configuration TN-S

No

System configuration TT

No

System configuration other

No

Number of poles

-

Lightning impulse current (10/350 µs)

6.25kA

Max. continuous voltage AC

-V

Max. continuous voltage DC

1500V

Nominal voltage AC

-V

Nominal voltage DC

-V

Max. PV-voltage

-V

Voltage protection level

4.5kV

Voltage protection level L-N

-kV

Voltage protection level L-PE

-kV

Voltage protection level N-PE

-kV

Voltage protection level (DC+ - DC-)

-kV

Voltage protection level (DC+/DC- - PE)

-kV

Follow current extinguishing capability

-kA

Specific energy (W/R)

-kJ/Ohm

Max. overcurrent protection device, series connection (fuse)

-A

Max. overcurrent protection device, parallel connection (fuse)

-A

Mounting method

DIN rail (top hat rail) 35 mm

Construction size

4 modular spacing

Max. conductor cross section solid (solid, stranded)

35mm²

Max. conductor cross section flexible (fine-strand)

35mm²

Remote signalling

No

Signalling at the device

Optic

Integrated backup fuse

No

Energy-coordinated protection effect with regard to the terminal equipment

No

Overcurrent protected voltage tapping

No

Voltage switching spark gap technology

No

Degree of protection (IP)

IP20


Warehouse states

Zagreb:

0 pcs

Zadar:

0 pcs


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

5094242 | V-PV-T1+2-1500FS

Main Product Image

Details

  • Earthing, lightning and surge protection
  • Combined arrester for power supply systems
  • 1 KOM
  • OBO

Technical specifications

System configuration DC

System configuration IT

System configuration TN

System configuration TN-C

System configuration TN-C-S

System configuration TN-S

System configuration TT

System configuration other

Number of poles

-

Lightning impulse current (10/350 µs)

6.25kA

Max. continuous voltage AC

-V

Max. continuous voltage DC

1500V

Nominal voltage AC

-V

Nominal voltage DC

-V

Max. PV-voltage

-V

Voltage protection level

4.5kV

Voltage protection level L-N

-kV

Voltage protection level L-PE

-kV

Voltage protection level N-PE

-kV

Voltage protection level (DC+ - DC-)

-kV

Voltage protection level (DC+/DC- - PE)

-kV

Follow current extinguishing capability

-kA

Specific energy (W/R)

-kJ/Ohm

Max. overcurrent protection device, series connection (fuse)

-A

Max. overcurrent protection device, parallel connection (fuse)

-A

Mounting method

DIN rail (top hat rail) 35 mm

Construction size

4 modular spacing

Max. conductor cross section solid (solid, stranded)

35mm²

Max. conductor cross section flexible (fine-strand)

35mm²

Remote signalling

Signalling at the device

Optic

Integrated backup fuse

Energy-coordinated protection effect with regard to the terminal equipment

Overcurrent protected voltage tapping

Voltage switching spark gap technology

Degree of protection (IP)