

Details
- Earthing, lightning and surge protection
- Combined arrester for power supply systems
- 1 KOM
- OBO
Technical specifications
Number of poles
-
Max. continuous voltage AC
-V
Nominal voltage AC
-V
Nominal voltage DC
-V
Max. PV-voltage
-V
Voltage protection level L-N
-kV
Voltage protection level L-PE
-kV
Voltage protection level N-PE
-kV
Voltage protection level (DC+ - DC-)
-kV
Voltage protection level (DC+/DC- - PE)
-kV
Follow current extinguishing capability
-kA
Specific energy (W/R)
-kJ/Ohm
Max. overcurrent protection device, series connection (fuse)
-A
Max. overcurrent protection device, parallel connection (fuse)
-A
Max. conductor cross section flexible (fine-strand)
35mm²
Remote signalling
No
Energy-coordinated protection effect with regard to the terminal equipment
No
Overcurrent protected voltage tapping
No
Voltage switching spark gap technology
No
System configuration IT
No
System configuration DC
Yes
System configuration TT
No
System configuration TN-C-S
No
System configuration TN-C
No
System configuration TN-S
No
System configuration other
No
Max. continuous voltage DC
1500V
Lightning impulse current (10/350 µs)
6.25kA
Voltage protection level
4.5kV
Mounting method
DIN rail (top hat rail) 35 mm
Signalling at the device
Optic
Integrated backup fuse
No
Degree of protection (IP)
IP20
Construction size
4 modular spacing
Max. conductor cross section solid (solid, stranded)
35mm²
System configuration TN
No
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
5094242 | V-PV-T1+2-1500FS

Details
- Earthing, lightning and surge protection
- Combined arrester for power supply systems
- 1 KOM
- OBO
Technical specifications
Number of poles
-
Max. continuous voltage AC
-V
Nominal voltage AC
-V
Nominal voltage DC
-V
Max. PV-voltage
-V
Voltage protection level L-N
-kV
Voltage protection level L-PE
-kV
Voltage protection level N-PE
-kV
Voltage protection level (DC+ - DC-)
-kV
Voltage protection level (DC+/DC- - PE)
-kV
Follow current extinguishing capability
-kA
Specific energy (W/R)
-kJ/Ohm
Max. overcurrent protection device, series connection (fuse)
-A
Max. overcurrent protection device, parallel connection (fuse)
-A
Max. conductor cross section flexible (fine-strand)
35mm²
Remote signalling
Energy-coordinated protection effect with regard to the terminal equipment
Overcurrent protected voltage tapping
Voltage switching spark gap technology
System configuration IT
System configuration DC
System configuration TT
System configuration TN-C-S
System configuration TN-C
System configuration TN-S
System configuration other
Max. continuous voltage DC
1500V
Lightning impulse current (10/350 µs)
6.25kA
Voltage protection level
4.5kV
Mounting method
DIN rail (top hat rail) 35 mm
Signalling at the device
Optic
Integrated backup fuse
Degree of protection (IP)
IP20
Construction size
4 modular spacing
Max. conductor cross section solid (solid, stranded)
35mm²
System configuration TN
From same serie
We use cookies to enhance your experience.