Details
- Earthing, lightning and surge protection
- Surge protection device for power supply systems
- 1 KOM
- EATON
Technical specifications
System configuration TN-C
Yes
System configuration TT
No
System configuration TN-S
Yes
System configuration IT
Yes
Number of conductors (without earthing)
3
System configuration TN-C-S
No
Max. continuous voltage DC
0V
Nominal voltage DC
0V
System configuration DC
No
Max. PV-voltage
0V
Voltage protection level L-N
0kV
System configuration other
Yes
Nominal discharge surge current (8/20)
20kA
Integrated backup fuse
No
Construction size
3 modular spacing
Mounting method
DIN rail (top hat rail) 35 mm
With remote signalling contact
No
Max. conductor cross section solid (solid, stranded)
25mm²
Integrated short-circuit protection selective to fuse gG
0A
Leakage-current free
No
Signalling at the device
Optic
Voltage protection level N-PE
0kV
System configuration TN
Yes
Max. conductor cross section flexible (fine-strand)
35mm²
Max. discharge surge current (8/20)
40kA
Degree of protection (IP)
IP20
Max. continuous voltage AC
460V
Category type 2
Yes
Voltage protection level
2.2kV
Max. overcurrent protection device, parallel connection (fuse)
0A
Max. overcurrent protection device, series connection (fuse)
125A
Short-circuit breaking capacity (Isccr)
0kA
Nominal voltage AC
460V
Integrated short-circuit protection
No
Warehouse states
Zagreb:
1 pcs
Zadar:
0 pcs
From same serie
SPCT2-460/3
Details
- Earthing, lightning and surge protection
- Surge protection device for power supply systems
- 1 KOM
- EATON
Technical specifications
System configuration TN-C
System configuration TT
System configuration TN-S
System configuration IT
Number of conductors (without earthing)
3
System configuration TN-C-S
Max. continuous voltage DC
0V
Nominal voltage DC
0V
System configuration DC
Max. PV-voltage
0V
Voltage protection level L-N
0kV
System configuration other
Nominal discharge surge current (8/20)
20kA
Integrated backup fuse
Construction size
3 modular spacing
Mounting method
DIN rail (top hat rail) 35 mm
With remote signalling contact
Max. conductor cross section solid (solid, stranded)
25mm²
Integrated short-circuit protection selective to fuse gG
0A
Leakage-current free
Signalling at the device
Optic
Voltage protection level N-PE
0kV
System configuration TN
Max. conductor cross section flexible (fine-strand)
35mm²
Max. discharge surge current (8/20)
40kA
Degree of protection (IP)
IP20
Max. continuous voltage AC
460V
Category type 2
Voltage protection level
2.2kV
Max. overcurrent protection device, parallel connection (fuse)
0A
Max. overcurrent protection device, series connection (fuse)
125A
Short-circuit breaking capacity (Isccr)
0kA
Nominal voltage AC
460V
Integrated short-circuit protection
From same serie