Aleta.hr

Details

  • Earthing, lightning and surge protection
  • Surge protection device for power supply systems
  • 1 KOM
  • EATON

Technical specifications

System configuration TN-C

Yes

System configuration TT

No

System configuration TN-S

Yes

System configuration IT

Yes

Number of conductors (without earthing)

3

System configuration TN-C-S

No

Max. continuous voltage DC

0V

Nominal voltage DC

0V

System configuration DC

No

Max. PV-voltage

0V

Voltage protection level L-N

0kV

System configuration other

Yes

Nominal discharge surge current (8/20)

20kA

Integrated backup fuse

No

Construction size

3 modular spacing

Mounting method

DIN rail (top hat rail) 35 mm

With remote signalling contact

No

Max. conductor cross section solid (solid, stranded)

25mm²

Integrated short-circuit protection selective to fuse gG

0A

Leakage-current free

No

Signalling at the device

Optic

Voltage protection level N-PE

0kV

System configuration TN

Yes

Max. conductor cross section flexible (fine-strand)

35mm²

Max. discharge surge current (8/20)

40kA

Degree of protection (IP)

IP20

Max. continuous voltage AC

460V

Category type 2

Yes

Voltage protection level

2.2kV

Max. overcurrent protection device, parallel connection (fuse)

0A

Max. overcurrent protection device, series connection (fuse)

125A

Short-circuit breaking capacity (Isccr)

0kA

Nominal voltage AC

460V

Integrated short-circuit protection

No


Warehouse states

Zagreb:

1 pcs

Zadar:

0 pcs


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

SPCT2-460/3

Main Product Image

Details

  • Earthing, lightning and surge protection
  • Surge protection device for power supply systems
  • 1 KOM
  • EATON

Technical specifications

System configuration TN-C

System configuration TT

System configuration TN-S

System configuration IT

Number of conductors (without earthing)

3

System configuration TN-C-S

Max. continuous voltage DC

0V

Nominal voltage DC

0V

System configuration DC

Max. PV-voltage

0V

Voltage protection level L-N

0kV

System configuration other

Nominal discharge surge current (8/20)

20kA

Integrated backup fuse

Construction size

3 modular spacing

Mounting method

DIN rail (top hat rail) 35 mm

With remote signalling contact

Max. conductor cross section solid (solid, stranded)

25mm²

Integrated short-circuit protection selective to fuse gG

0A

Leakage-current free

Signalling at the device

Optic

Voltage protection level N-PE

0kV

System configuration TN

Max. conductor cross section flexible (fine-strand)

35mm²

Max. discharge surge current (8/20)

40kA

Degree of protection (IP)

IP20

Max. continuous voltage AC

460V

Category type 2

Voltage protection level

2.2kV

Max. overcurrent protection device, parallel connection (fuse)

0A

Max. overcurrent protection device, series connection (fuse)

125A

Short-circuit breaking capacity (Isccr)

0kA

Nominal voltage AC

460V

Integrated short-circuit protection

From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

We use cookies to enhance your experience.