Aleta.hr
Main Product Image

2CDA383799R0201 M303P D20

Code: 2016284

ManufacturerRAZNO
Catalog number2CDA383799R0201
Type
EAN code4016779090117

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth

69mm

Rated current

20A

Rated voltage

-V

Number of protected poles

3

Rated impulse withstand voltage Uimp

6kV

Release characteristic

Other

Rated insulation voltage Ui

500V

Number of poles (total)

3

Voltage type

Other

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

25kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Frequency

50 - 60Hz

Power loss

-W

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Current limiting class

-

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Pollution degree

3

Concurrently switching neutral conductor

No

Flush-mounted installation

No

Over voltage category

4

Connectable conductor cross section multi-wired

0.75 - 25mm²

Additional equipment possible

Yes

Ambient temperature during operating

-40 - 70°C

Connectable conductor cross section solid-core

0.75 - 35mm²

Width in number of modular spacings

3.0

Explosion-proof

No

Degree of protection (IP)

IP20


Warehouse states

Zagreb:

0 pcs

Zadar:

0 pcs


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

2CDA383799R0201 M303P D20

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth

69mm

Rated current

20A

Rated voltage

-V

Number of protected poles

3

Rated impulse withstand voltage Uimp

6kV

Release characteristic

Other

Rated insulation voltage Ui

500V

Number of poles (total)

3

Voltage type

Other

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

25kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Frequency

50 .. 60Hz

Power loss

-W

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Current limiting class

-

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Pollution degree

3

Concurrently switching neutral conductor

Flush-mounted installation

Over voltage category

4

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Additional equipment possible

Ambient temperature during operating

-40 .. 70°C

Connectable conductor cross section solid-core

0.75 .. 35mm²

Width in number of modular spacings

3.0

Explosion-proof

Degree of protection (IP)

IP20

From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

We use cookies to enhance your experience.