Aleta.hr
Main Product Image

2CDA381799R0361 M301P D6 3

Code: 2016271

ManufacturerRAZNO
Catalog number2CDA381799R0361
Type
EAN code4016779089265

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth

69mm

Number of poles (total)

1

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Number of protected poles

1

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Voltage type

Other

Rated insulation voltage Ui

500V

Rated voltage

-V

Rated current

6.3A

Rated impulse withstand voltage Uimp

6kV

Release characteristic

Other

Power loss

-W

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

25kA

Current limiting class

-

Frequency

50 - 60Hz

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Concurrently switching neutral conductor

No

Additional equipment possible

Yes

Pollution degree

3

Flush-mounted installation

No

Width in number of modular spacings

1.0

Explosion-proof

No

Connectable conductor cross section multi-wired

0.75 - 25mm²

Over voltage category

4

Degree of protection (IP)

IP20

Connectable conductor cross section solid-core

0.75 - 35mm²

Ambient temperature during operating

-40 - 70°C


Warehouse states

Zagreb:

0 pcs

Zadar:

0 pcs


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

2CDA381799R0361 M301P D6 3

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth

69mm

Number of poles (total)

1

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Number of protected poles

1

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Voltage type

Other

Rated insulation voltage Ui

500V

Rated voltage

-V

Rated current

6.3A

Rated impulse withstand voltage Uimp

6kV

Release characteristic

Other

Power loss

-W

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

25kA

Current limiting class

-

Frequency

50 .. 60Hz

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Concurrently switching neutral conductor

Additional equipment possible

Pollution degree

3

Flush-mounted installation

Width in number of modular spacings

1.0

Explosion-proof

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Over voltage category

4

Degree of protection (IP)

IP20

Connectable conductor cross section solid-core

0.75 .. 35mm²

Ambient temperature during operating

-40 .. 70°C

From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

We use cookies to enhance your experience.