Aleta.hr
Main Product Image

2CDA384799R0491 | M304P-D12,5

Code: 2015505

ManufacturerRAZNO
Catalog number2CDA384799R0491
Type
EAN code4016779090322

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth

69mm

Number of poles (total)

4

Rated current

12.5A

Rated insulation voltage Ui

500V

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Number of protected poles

4

Rated impulse withstand voltage Uimp

6kV

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

25kA

Current limiting class

-

Voltage type

Other

Rated voltage

-V

Frequency

50 - 60Hz

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Release characteristic

Other

Power loss

-W

Flush-mounted installation

No

Explosion-proof

No

Pollution degree

3

Connectable conductor cross section multi-wired

0.75 - 25mm²

Concurrently switching neutral conductor

No

Additional equipment possible

Yes

Width in number of modular spacings

4.0

Over voltage category

4

Degree of protection (IP)

IP20

Ambient temperature during operating

-40 - 70°C

Connectable conductor cross section solid-core

0.75 - 35mm²


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

2CDA384799R0491 | M304P-D12,5

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth

69mm

Number of poles (total)

4

Rated current

12.5A

Rated insulation voltage Ui

500V

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Number of protected poles

4

Rated impulse withstand voltage Uimp

6kV

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

25kA

Current limiting class

-

Voltage type

Other

Rated voltage

-V

Frequency

50 .. 60Hz

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Release characteristic

Other

Power loss

-W

Flush-mounted installation

Explosion-proof

Pollution degree

3

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Concurrently switching neutral conductor

Additional equipment possible

Width in number of modular spacings

4.0

Over voltage category

4

Degree of protection (IP)

IP20

Ambient temperature during operating

-40 .. 70°C

Connectable conductor cross section solid-core

0.75 .. 35mm²

From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.