Aleta.hr
Main Product Image

2CDA382799R0631 | M302P-D63

Code: 2015491

ManufacturerRAZNO
Catalog number2CDA382799R0631
Type
EAN code4016779089456

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Number of poles (total)

2

Built-in depth

69mm

Number of protected poles

2

Release characteristic

Other

Rated impulse withstand voltage Uimp

6kV

Rated voltage

-V

Voltage type

Other

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Rated insulation voltage Ui

500V

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Rated current

63A

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Power loss

-W

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

25kA

Frequency

50 - 60Hz

Current limiting class

-

Flush-mounted installation

No

Over voltage category

4

Concurrently switching neutral conductor

No

Ambient temperature during operating

-40 - 70°C

Pollution degree

3

Additional equipment possible

Yes

Width in number of modular spacings

2.0

Connectable conductor cross section solid-core

0.75 - 35mm²

Connectable conductor cross section multi-wired

0.75 - 25mm²

Degree of protection (IP)

IP20

Explosion-proof

No


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

2CDA382799R0631 | M302P-D63

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Number of poles (total)

2

Built-in depth

69mm

Number of protected poles

2

Release characteristic

Other

Rated impulse withstand voltage Uimp

6kV

Rated voltage

-V

Voltage type

Other

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Rated insulation voltage Ui

500V

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Rated current

63A

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Power loss

-W

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

25kA

Frequency

50 .. 60Hz

Current limiting class

-

Flush-mounted installation

Over voltage category

4

Concurrently switching neutral conductor

Ambient temperature during operating

-40 .. 70°C

Pollution degree

3

Additional equipment possible

Width in number of modular spacings

2.0

Connectable conductor cross section solid-core

0.75 .. 35mm²

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Degree of protection (IP)

IP20

Explosion-proof

From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.