Details
- Earthing, lightning and surge protection
- Surge protection device for power supply systems
- 1 KOM
- ABB
Technical specifications
System configuration TN-C
No
System configuration DC
Yes
System configuration TN-C-S
No
System configuration TN-S
No
System configuration other
No
System configuration TT
No
System configuration IT
No
System configuration TN
No
Max. discharge surge current (8/20)
20kA
Nominal discharge surge current (8/20)
20kA
Max. PV-voltage
1500V
Nominal voltage AC
-V
Max. continuous voltage AC
1500V
Nominal voltage DC
1500V
Number of conductors (without earthing)
2
Max. continuous voltage DC
1500V
Integrated short-circuit protection selective to fuse gG
-A
Integrated short-circuit protection
No
Max. overcurrent protection device, series connection (fuse)
-A
Max. overcurrent protection device, parallel connection (fuse)
-A
Short-circuit breaking capacity (Isccr)
10kA
Voltage protection level L-N
-kV
Voltage protection level N-PE
-kV
Voltage protection level
4kV
Mounting method
Other
Leakage-current free
No
Integrated backup fuse
No
Signalling at the device
Optic
Construction size
3 modular spacing
Degree of protection (IP)
IP20
Max. conductor cross section flexible (fine-strand)
25mm²
Category type 2
Yes
Max. conductor cross section solid (solid, stranded)
35mm²
With remote signalling contact
No
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
2CTB802400R1500 | OVR PV T2 40-1500 P

Details
- Earthing, lightning and surge protection
- Surge protection device for power supply systems
- 1 KOM
- ABB
Technical specifications
System configuration TN-C
System configuration DC
System configuration TN-C-S
System configuration TN-S
System configuration other
System configuration TT
System configuration IT
System configuration TN
Max. discharge surge current (8/20)
20kA
Nominal discharge surge current (8/20)
20kA
Max. PV-voltage
1500V
Nominal voltage AC
-V
Max. continuous voltage AC
1500V
Nominal voltage DC
1500V
Number of conductors (without earthing)
2
Max. continuous voltage DC
1500V
Integrated short-circuit protection selective to fuse gG
-A
Integrated short-circuit protection
Max. overcurrent protection device, series connection (fuse)
-A
Max. overcurrent protection device, parallel connection (fuse)
-A
Short-circuit breaking capacity (Isccr)
10kA
Voltage protection level L-N
-kV
Voltage protection level N-PE
-kV
Voltage protection level
4kV
Mounting method
Other
Leakage-current free
Integrated backup fuse
Signalling at the device
Optic
Construction size
3 modular spacing
Degree of protection (IP)
IP20
Max. conductor cross section flexible (fine-strand)
25mm²
Category type 2
Max. conductor cross section solid (solid, stranded)
35mm²
With remote signalling contact
From same serie
We use cookies to enhance your experience.