Technical specifications

Rated voltage

230V

Number of poles (total)

2

Rated impulse withstand voltage Uimp

4kV

Leakage current type

A

Rated insulation voltage Ui

440V

Rated fault current

0.03A

Current limiting class

3

Number of protected poles

2

Surge current capacity

0.25kA

Rated short-circuit breaking capacity Icn according to EN 61009-1

10kA

Power loss

3.74W

Voltage type

AC

Rated short-circuit breaking capacity according to IEC 60947-2

10kA

Disconnection characteristic

Undelayed

Rated current

13A

Rated short-circuit breaking capacity according to EN 61009

10kA

Over voltage category

3

Frequency

50/60 Hz

Flush-mounted installation

No

Built-in depth

72mm

Concurrently switching neutral conductor

Yes

Connectable conductor cross section solid-core

- - -mm²

Degree of protection (IP)

IP20

With interlocking device

No

Pollution degree

3

Anti-nuisance tripping version

No

Release characteristic

C

Connectable conductor cross section multi-wired

1 - 25mm²

Width in number of modular spacings

2

Ambient temperature during operating

-25 - 55°C


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

2CSR772198R1135 | DS202CR M B13 A30 50/60

Main Product Image

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Rated voltage

230V

Number of poles (total)

2

Rated impulse withstand voltage Uimp

4kV

Leakage current type

A

Rated insulation voltage Ui

440V

Rated fault current

0.03A

Current limiting class

3

Number of protected poles

2

Surge current capacity

0.25kA

Rated short-circuit breaking capacity Icn according to EN 61009-1

10kA

Power loss

3.74W

Voltage type

AC

Rated short-circuit breaking capacity according to IEC 60947-2

10kA

Disconnection characteristic

Undelayed

Rated current

13A

Rated short-circuit breaking capacity according to EN 61009

10kA

Over voltage category

3

Frequency

50/60 Hz

Flush-mounted installation

Built-in depth

72mm

Concurrently switching neutral conductor

Connectable conductor cross section solid-core

- .. -mm²

Degree of protection (IP)

IP20

With interlocking device

Pollution degree

3

Anti-nuisance tripping version

Release characteristic

C

Connectable conductor cross section multi-wired

1 .. 25mm²

Width in number of modular spacings

2

Ambient temperature during operating

-25 .. 55°C

From same serie