Technical specifications

Number of poles (total)

2

Rated voltage

230V

Rated insulation voltage Ui

440V

Rated impulse withstand voltage Uimp

4kV

Rated fault current

0.3A

Number of protected poles

2

Power loss

3.28W

Current limiting class

3

Leakage current type

A

Rated current

10A

Rated short-circuit breaking capacity according to EN 61009

6kA

Disconnection characteristic

Undelayed

Rated short-circuit breaking capacity according to IEC 60947-2

10kA

Rated short-circuit breaking capacity Icn according to EN 61009-1

6kA

Voltage type

AC

Surge current capacity

0.25kA

Release characteristic

C

Frequency

50 Hz

With interlocking device

No

Pollution degree

3

Over voltage category

3

Built-in depth

72mm

Width in number of modular spacings

2

Anti-nuisance tripping version

No

Concurrently switching neutral conductor

Yes

Degree of protection (IP)

IP20

Connectable conductor cross section solid-core

- - -mm²

Ambient temperature during operating

-25 - 55°C

Connectable conductor cross section multi-wired

1 - 25mm²

Flush-mounted installation

No


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

2CSR752140R3104 | DS202CR C10 A300

Main Product Image

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Number of poles (total)

2

Rated voltage

230V

Rated insulation voltage Ui

440V

Rated impulse withstand voltage Uimp

4kV

Rated fault current

0.3A

Number of protected poles

2

Power loss

3.28W

Current limiting class

3

Leakage current type

A

Rated current

10A

Rated short-circuit breaking capacity according to EN 61009

6kA

Disconnection characteristic

Undelayed

Rated short-circuit breaking capacity according to IEC 60947-2

10kA

Rated short-circuit breaking capacity Icn according to EN 61009-1

6kA

Voltage type

AC

Surge current capacity

0.25kA

Release characteristic

C

Frequency

50 Hz

With interlocking device

Pollution degree

3

Over voltage category

3

Built-in depth

72mm

Width in number of modular spacings

2

Anti-nuisance tripping version

Concurrently switching neutral conductor

Degree of protection (IP)

IP20

Connectable conductor cross section solid-core

- .. -mm²

Ambient temperature during operating

-25 .. 55°C

Connectable conductor cross section multi-wired

1 .. 25mm²

Flush-mounted installation