Aleta.hr
Main Product Image

2CDS274565R0558 | S204MTR-Z40 DC

Code: 2003777

ManufacturerRAZNO
Catalog number2CDS274565R0558
Type
EAN code4016779136136

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated current

40A

Built-in depth

69mm

Release characteristic

Z

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Number of protected poles

4

Rated insulation voltage Ui

440V

Current limiting class

3

Voltage type

Other

Number of poles (total)

4

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

10kA

Rated voltage

440V

Frequency

50 - 60Hz

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

10kA

Power loss

17.2W

Degree of protection (IP)

IP20

Flush-mounted installation

No

Pollution degree

3

Concurrently switching neutral conductor

No

Additional equipment possible

Yes

Over voltage category

3

Connectable conductor cross section solid-core

0.75 - 35mm²

Connectable conductor cross section multi-wired

0.75 - 25mm²

Width in number of modular spacings

4.0

Ambient temperature during operating

-40 - 75°C

Explosion-proof

No


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

2CDS274565R0558 | S204MTR-Z40 DC

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated current

40A

Built-in depth

69mm

Release characteristic

Z

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Number of protected poles

4

Rated insulation voltage Ui

440V

Current limiting class

3

Voltage type

Other

Number of poles (total)

4

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

10kA

Rated voltage

440V

Frequency

50 .. 60Hz

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

10kA

Power loss

17.2W

Degree of protection (IP)

IP20

Flush-mounted installation

Pollution degree

3

Concurrently switching neutral conductor

Additional equipment possible

Over voltage category

3

Connectable conductor cross section solid-core

0.75 .. 35mm²

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Width in number of modular spacings

4.0

Ambient temperature during operating

-40 .. 75°C

Explosion-proof

From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

We use cookies to enhance your experience.