Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated current

8A

Release characteristic

K

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Rated insulation voltage Ui

440V

Rated voltage

440V

Number of poles (total)

4

Number of protected poles

4

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

10kA

Current limiting class

3

Power loss

4.8W

Frequency

50 - 60Hz

Built-in depth

69mm

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

10kA

Voltage type

Other

Over voltage category

3

Flush-mounted installation

No

Additional equipment possible

Yes

Pollution degree

3

Connectable conductor cross section solid-core

0.75 - 35mm²

Ambient temperature during operating

-40 - 75°C

Concurrently switching neutral conductor

No

Explosion-proof

No

Degree of protection (IP)

IP20

Width in number of modular spacings

4.0

Connectable conductor cross section multi-wired

0.75 - 25mm²


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

2CDS274565R0407 | S204MTR-K8 DC

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated current

8A

Release characteristic

K

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Rated insulation voltage Ui

440V

Rated voltage

440V

Number of poles (total)

4

Number of protected poles

4

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

10kA

Current limiting class

3

Power loss

4.8W

Frequency

50 .. 60Hz

Built-in depth

69mm

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

10kA

Voltage type

Other

Over voltage category

3

Flush-mounted installation

Additional equipment possible

Pollution degree

3

Connectable conductor cross section solid-core

0.75 .. 35mm²

Ambient temperature during operating

-40 .. 75°C

Concurrently switching neutral conductor

Explosion-proof

Degree of protection (IP)

IP20

Width in number of modular spacings

4.0

Connectable conductor cross section multi-wired

0.75 .. 25mm²