Aleta.hr
Main Product Image

2CDS273447R0518 | S203MTR-Z25

Code: 2003542

ManufacturerRAZNO
Catalog number2CDS273447R0518
Type
EAN code4016779105644

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Release characteristic

Z

Number of protected poles

3

Built-in depth

69mm

Rated current

25A

Rated voltage

440V

Rated insulation voltage Ui

440V

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Voltage type

Other

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

25kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

25kA

Frequency

50 - 60Hz

Power loss

9.3W

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

25kA

Current limiting class

3

Number of poles (total)

3

Flush-mounted installation

No

Degree of protection (IP)

IP20

Over voltage category

3

Pollution degree

3

Concurrently switching neutral conductor

No

Connectable conductor cross section multi-wired

0.75 - 25mm²

Additional equipment possible

Yes

Ambient temperature during operating

-40 - 75°C

Width in number of modular spacings

3.0

Connectable conductor cross section solid-core

0.75 - 35mm²

Explosion-proof

No


Warehouse states

Zagreb:

0 pcs

Zadar:

0 pcs


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

2CDS273447R0518 | S203MTR-Z25

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Release characteristic

Z

Number of protected poles

3

Built-in depth

69mm

Rated current

25A

Rated voltage

440V

Rated insulation voltage Ui

440V

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Voltage type

Other

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

25kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

25kA

Frequency

50 .. 60Hz

Power loss

9.3W

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

25kA

Current limiting class

3

Number of poles (total)

3

Flush-mounted installation

Degree of protection (IP)

IP20

Over voltage category

3

Pollution degree

3

Concurrently switching neutral conductor

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Additional equipment possible

Ambient temperature during operating

-40 .. 75°C

Width in number of modular spacings

3.0

Connectable conductor cross section solid-core

0.75 .. 35mm²

Explosion-proof

From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

We use cookies to enhance your experience.