Technical specifications

Built-in depth

82.5mm

Voltage type

Other

Number of protected poles

4

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Release characteristic

K

Rated voltage

-V

Current limiting class

3

Number of poles (total)

4

Power loss

6.4W

Rated current

80A

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

50kA

Rated impulse withstand voltage Uimp

8kV

Rated insulation voltage Ui

690V

Frequency

50 - 60Hz

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Flush-mounted installation

No

Additional equipment possible

Yes

Ambient temperature during operating

-25 - 60°C

Pollution degree

2

Over voltage category

3

Degree of protection (IP)

IP20

Concurrently switching neutral conductor

No

Connectable conductor cross section solid-core

0 - 70mm²

Explosion-proof

No

Width in number of modular spacings

6

Connectable conductor cross section multi-wired

0 - 50mm²


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

2CCS864017R0627 | S804U-K80

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth

82.5mm

Voltage type

Other

Number of protected poles

4

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Release characteristic

K

Rated voltage

-V

Current limiting class

3

Number of poles (total)

4

Power loss

6.4W

Rated current

80A

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

50kA

Rated impulse withstand voltage Uimp

8kV

Rated insulation voltage Ui

690V

Frequency

50 .. 60Hz

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Flush-mounted installation

Additional equipment possible

Ambient temperature during operating

-25 .. 60°C

Pollution degree

2

Over voltage category

3

Degree of protection (IP)

IP20

Concurrently switching neutral conductor

Connectable conductor cross section solid-core

0 .. 70mm²

Explosion-proof

Width in number of modular spacings

6

Connectable conductor cross section multi-wired

0 .. 50mm²