Aleta.hr
Main Product Image

2CCS864017R0487 | S804U-K20

Code: 1999909

ManufacturerRAZNO
Catalog number2CCS864017R0487
Type
EAN code7612271214111

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated current

20A

Rated insulation voltage Ui

690V

Rated impulse withstand voltage Uimp

8kV

Number of protected poles

4

Number of poles (total)

4

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Rated voltage

-V

Release characteristic

K

Built-in depth

82.5mm

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Voltage type

Other

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

50kA

Frequency

50 - 60Hz

Current limiting class

3

Power loss

3.5W

Pollution degree

2

Additional equipment possible

Yes

Flush-mounted installation

No

Explosion-proof

No

Concurrently switching neutral conductor

No

Degree of protection (IP)

IP20

Connectable conductor cross section multi-wired

0 - 50mm²

Width in number of modular spacings

6

Connectable conductor cross section solid-core

0 - 70mm²

Ambient temperature during operating

-25 - 60°C

Over voltage category

3


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

2CCS864017R0487 | S804U-K20

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated current

20A

Rated insulation voltage Ui

690V

Rated impulse withstand voltage Uimp

8kV

Number of protected poles

4

Number of poles (total)

4

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Rated voltage

-V

Release characteristic

K

Built-in depth

82.5mm

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Voltage type

Other

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

50kA

Frequency

50 .. 60Hz

Current limiting class

3

Power loss

3.5W

Pollution degree

2

Additional equipment possible

Flush-mounted installation

Explosion-proof

Concurrently switching neutral conductor

Degree of protection (IP)

IP20

Connectable conductor cross section multi-wired

0 .. 50mm²

Width in number of modular spacings

6

Connectable conductor cross section solid-core

0 .. 70mm²

Ambient temperature during operating

-25 .. 60°C

Over voltage category

3

From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

We use cookies to enhance your experience.