2CCL563310E0324 | FS403MK-C32/0.03

Code: 1999798

ManufacturerABB
Catalog number2CCL563310E0324
EAN code7612271470838
Order only
Zagreb0 pcs
Zadar0 pcs

Sign in or create an account for lower prices and other benefits


WSP*
339,12 €
Neto339,12
RP423,90
pcs

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Suitable for flush-mounted installation

No

Number of poles (total)

4

Number of protected poles

3

Rated voltage

415V

Rated insulation voltage Ui

500V

Rated impulse withstand voltage Uimp

4kV

Rated current

32A

Rated fault current

0.03A

Leakage current type

F

Current limiting class

3

Power loss

12.6W

Rated short-circuit breaking capacity according to EN 61009

10kA

Rated short-circuit breaking capacity according to IEC 60947-2

15kA

Rated short-circuit breaking capacity Icn according to EN 61009-1

10kA

Disconnection characteristic

Undelayed

Surge current capacity

3kA

Voltage type

AC

Frequency

50/60 Hz

Release characteristic

C

Concurrently switching neutral conductor

Yes

With interlocking device

Yes

Over voltage category

3

Pollution degree

2

Ambient temperature during operating

-25 - 60°C

Width in number of modular spacings

4

Built-in depth

91mm

Flush-mounted installation

No

Anti-nuisance tripping version

No

Degree of protection (IP)

IP20

Connectable conductor cross section solid-core

- - -mm²

Connectable conductor cross section multi-wired

0.75 - 25mm²


Warehouse states

Zagreb:

0 pcs

Zadar:

0 pcs


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

2CCL563310E0324 | FS403MK-C32/0.03

Main Product Image

Code

1999798

Catalog number

2CCL563310E0324

Type

Earth leakage circuit breaker

Manufacturer

ABB

Serie

-

Neto WSP:

339,12

RP:423,90
* Minimum quantity1

Total stock:

0 PCS

Zadar0 PCS
Zagreb0 PCS

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Suitable for flush-mounted installation

Number of poles (total)

4

Number of protected poles

3

Rated voltage

415V

Rated insulation voltage Ui

500V

Rated impulse withstand voltage Uimp

4kV

Rated current

32A

Rated fault current

0.03A

Leakage current type

F

Current limiting class

3

Power loss

12.6W

Rated short-circuit breaking capacity according to EN 61009

10kA

Rated short-circuit breaking capacity according to IEC 60947-2

15kA

Rated short-circuit breaking capacity Icn according to EN 61009-1

10kA

Disconnection characteristic

Undelayed

Surge current capacity

3kA

Voltage type

AC

Frequency

50/60 Hz

Release characteristic

C

Concurrently switching neutral conductor

With interlocking device

Over voltage category

3

Pollution degree

2

Ambient temperature during operating

-25 .. 60°C

Width in number of modular spacings

4

Built-in depth

91mm

Flush-mounted installation

Anti-nuisance tripping version

Degree of protection (IP)

IP20

Connectable conductor cross section solid-core

- .. -mm²

Connectable conductor cross section multi-wired

0.75 .. 25mm²

From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

We use cookies to enhance your experience.