Aleta.hr
Aleta.hr
Main Product Image

2CCL562122E0254 | FS401 M-C25/0.1 - RCBO

Code: 1999762

ManufacturerRAZNO
Catalog number2CCL562122E0254
Type
EAN code7612271490744

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Suitable for flush-mounted installation

No

Number of poles (total)

2

Number of protected poles

1

Rated voltage

240V

Rated insulation voltage Ui

500V

Rated impulse withstand voltage Uimp

4kV

Rated current

25A

Rated fault current

0.1A

Leakage current type

A

Current limiting class

3

Power loss

4.4W

Rated short-circuit breaking capacity according to EN 61009

10kA

Rated short-circuit breaking capacity according to IEC 60947-2

15kA

Rated short-circuit breaking capacity Icn according to EN 61009-1

10kA

Disconnection characteristic

Undelayed

Surge current capacity

0.25kA

Voltage type

AC

Frequency

50/60 Hz

Release characteristic

C

Concurrently switching neutral conductor

Yes

With interlocking device

Yes

Over voltage category

3

Pollution degree

2

Ambient temperature during operating

-25 - 60°C

Width in number of modular spacings

2

Built-in depth

91mm

Flush-mounted installation

No

Anti-nuisance tripping version

No

Degree of protection (IP)

IP20

Connectable conductor cross section solid-core

- - -mm²

Connectable conductor cross section multi-wired

0.75 - 25mm²


Warehouse states

Zagreb:

0 pcs

Zadar:

0 pcs


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

Code: 1999762

2CCL562122E0254 | FS401 M-C25/0.1 - RCBO

Main Product Image

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Suitable for flush-mounted installation

Number of poles (total)

2

Number of protected poles

1

Rated voltage

240V

Rated insulation voltage Ui

500V

Rated impulse withstand voltage Uimp

4kV

Rated current

25A

Rated fault current

0.1A

Leakage current type

A

Current limiting class

3

Power loss

4.4W

Rated short-circuit breaking capacity according to EN 61009

10kA

Rated short-circuit breaking capacity according to IEC 60947-2

15kA

Rated short-circuit breaking capacity Icn according to EN 61009-1

10kA

Disconnection characteristic

Undelayed

Surge current capacity

0.25kA

Voltage type

AC

Frequency

50/60 Hz

Release characteristic

C

Concurrently switching neutral conductor

With interlocking device

Over voltage category

3

Pollution degree

2

Ambient temperature during operating

-25 .. 60°C

Width in number of modular spacings

2

Built-in depth

91mm

Flush-mounted installation

Anti-nuisance tripping version

Degree of protection (IP)

IP20

Connectable conductor cross section solid-core

- .. -mm²

Connectable conductor cross section multi-wired

0.75 .. 25mm²