Aleta.hr
Main Product Image

2CCG000476R0001 | S401P-B10NP

Code: 1999636

ManufacturerRAZNO
Catalog number2CCG000476R0001
Type
EAN code7612271508609

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Number of poles (total)

2

Release characteristic

B

Number of protected poles

2

Rated current

10A

Built-in depth

91mm

Rated voltage

240V

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Rated impulse withstand voltage Uimp

4kV

Rated insulation voltage Ui

440V

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Voltage type

Other

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

40kA

Current limiting class

3

Frequency

50 - 60Hz

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

40kA

Power loss

2.6W

Additional equipment possible

Yes

Degree of protection (IP)

IP20

Over voltage category

3

Ambient temperature during operating

-25 - 60°C

Flush-mounted installation

No

Concurrently switching neutral conductor

Yes

Connectable conductor cross section multi-wired

0.75 - 25mm²

Width in number of modular spacings

2

Connectable conductor cross section solid-core

0.75 - 35mm²

Explosion-proof

No

Pollution degree

3


Warehouse states

Zagreb:

0 pcs

Zadar:

0 pcs


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

2CCG000476R0001 | S401P-B10NP

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Number of poles (total)

2

Release characteristic

B

Number of protected poles

2

Rated current

10A

Built-in depth

91mm

Rated voltage

240V

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Rated impulse withstand voltage Uimp

4kV

Rated insulation voltage Ui

440V

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Voltage type

Other

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

40kA

Current limiting class

3

Frequency

50 .. 60Hz

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

40kA

Power loss

2.6W

Additional equipment possible

Degree of protection (IP)

IP20

Over voltage category

3

Ambient temperature during operating

-25 .. 60°C

Flush-mounted installation

Concurrently switching neutral conductor

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Width in number of modular spacings

2

Connectable conductor cross section solid-core

0.75 .. 35mm²

Explosion-proof

Pollution degree

3

From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.