Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth

91mm

Rated current

8A

Release characteristic

B

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Number of poles (total)

2

Voltage type

Other

Rated voltage

240V

Rated impulse withstand voltage Uimp

4kV

Number of protected poles

2

Rated insulation voltage Ui

440V

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Frequency

50 - 60Hz

Power loss

2.4W

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

40kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

40kA

Current limiting class

3

Additional equipment possible

Yes

Flush-mounted installation

No

Over voltage category

3

Concurrently switching neutral conductor

Yes

Degree of protection (IP)

IP20

Pollution degree

3

Width in number of modular spacings

2

Connectable conductor cross section multi-wired

0.75 - 25mm²

Explosion-proof

No

Connectable conductor cross section solid-core

0.75 - 35mm²

Ambient temperature during operating

-25 - 60°C


Warehouse states

Zagreb:

0 pcs

Zadar:

0 pcs


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

2CCG000464R0001 | S401P-B8NP

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth

91mm

Rated current

8A

Release characteristic

B

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Number of poles (total)

2

Voltage type

Other

Rated voltage

240V

Rated impulse withstand voltage Uimp

4kV

Number of protected poles

2

Rated insulation voltage Ui

440V

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Frequency

50 .. 60Hz

Power loss

2.4W

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

40kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

40kA

Current limiting class

3

Additional equipment possible

Flush-mounted installation

Over voltage category

3

Concurrently switching neutral conductor

Degree of protection (IP)

IP20

Pollution degree

3

Width in number of modular spacings

2

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Explosion-proof

Connectable conductor cross section solid-core

0.75 .. 35mm²

Ambient temperature during operating

-25 .. 60°C