Aleta.hr
Main Product Image

2CCG000433R0001 | S401P-K13NP

Code: 1999593

ManufacturerRAZNO
Catalog number2CCG000433R0001
Type
EAN code7612271510015

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Number of poles (total)

2

Number of protected poles

2

Built-in depth

91mm

Rated insulation voltage Ui

440V

Rated voltage

240V

Release characteristic

K

Power loss

3.4W

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

40kA

Frequency

50 - 60Hz

Voltage type

Other

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

40kA

Current limiting class

3

Rated current

13A

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Over voltage category

3

Concurrently switching neutral conductor

Yes

Connectable conductor cross section multi-wired

0.75 - 25mm²

Degree of protection (IP)

IP20

Connectable conductor cross section solid-core

0.75 - 35mm²

Width in number of modular spacings

2

Flush-mounted installation

No

Ambient temperature during operating

-25 - 60°C

Pollution degree

3

Additional equipment possible

Yes

Explosion-proof

No


Warehouse states

Zagreb:

0 pcs

Zadar:

0 pcs


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

2CCG000433R0001 | S401P-K13NP

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Number of poles (total)

2

Number of protected poles

2

Built-in depth

91mm

Rated insulation voltage Ui

440V

Rated voltage

240V

Release characteristic

K

Power loss

3.4W

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

40kA

Frequency

50 .. 60Hz

Voltage type

Other

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

40kA

Current limiting class

3

Rated current

13A

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Over voltage category

3

Concurrently switching neutral conductor

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Degree of protection (IP)

IP20

Connectable conductor cross section solid-core

0.75 .. 35mm²

Width in number of modular spacings

2

Flush-mounted installation

Ambient temperature during operating

-25 .. 60°C

Pollution degree

3

Additional equipment possible

Explosion-proof

From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

We use cookies to enhance your experience.