Aleta.hr
Main Product Image

2CCG000403R0001 | S403P-C16NP

Code: 1999563

ManufacturerRAZNO
Catalog number2CCG000403R0001
Type
EAN code7612271509743

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Release characteristic

C

Built-in depth

91mm

Voltage type

Other

Number of poles (total)

4

Rated current

16A

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Number of protected poles

4

Rated insulation voltage Ui

440V

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Power loss

7.6W

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

40kA

Rated voltage

240V

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

40kA

Frequency

50 - 60Hz

Current limiting class

3

Flush-mounted installation

No

Ambient temperature during operating

-25 - 60°C

Connectable conductor cross section solid-core

0.75 - 35mm²

Over voltage category

3

Additional equipment possible

Yes

Pollution degree

3

Explosion-proof

No

Width in number of modular spacings

4

Degree of protection (IP)

IP20

Concurrently switching neutral conductor

Yes

Connectable conductor cross section multi-wired

0.75 - 25mm²


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

2CCG000403R0001 | S403P-C16NP

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Release characteristic

C

Built-in depth

91mm

Voltage type

Other

Number of poles (total)

4

Rated current

16A

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Number of protected poles

4

Rated insulation voltage Ui

440V

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Power loss

7.6W

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

40kA

Rated voltage

240V

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

40kA

Frequency

50 .. 60Hz

Current limiting class

3

Flush-mounted installation

Ambient temperature during operating

-25 .. 60°C

Connectable conductor cross section solid-core

0.75 .. 35mm²

Over voltage category

3

Additional equipment possible

Pollution degree

3

Explosion-proof

Width in number of modular spacings

4

Degree of protection (IP)

IP20

Concurrently switching neutral conductor

Connectable conductor cross section multi-wired

0.75 .. 25mm²