Aleta.hr
Main Product Image

2CCG000145R0001 | SUP401M-K6

Code: 1999464

ManufacturerRAZNO
Catalog number2CCG000145R0001
Type
EAN code7612271506780

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Number of protected poles

1

Number of poles (total)

1

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Built-in depth

102mm

Release characteristic

K

Rated impulse withstand voltage Uimp

4kV

Voltage type

Other

Rated insulation voltage Ui

500V

Rated current

6A

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

40kA

Rated voltage

240V

Frequency

50 - 60Hz

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

40kA

Power loss

1.6W

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Current limiting class

3

Flush-mounted installation

No

Pollution degree

2

Over voltage category

3

Concurrently switching neutral conductor

No

Width in number of modular spacings

18

Connectable conductor cross section multi-wired

0.75 - 25mm²

Ambient temperature during operating

-25 - 60°C

Explosion-proof

No

Degree of protection (IP)

IP20

Connectable conductor cross section solid-core

0.75 - 35mm²

Additional equipment possible

Yes


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

2CCG000145R0001 | SUP401M-K6

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Number of protected poles

1

Number of poles (total)

1

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Built-in depth

102mm

Release characteristic

K

Rated impulse withstand voltage Uimp

4kV

Voltage type

Other

Rated insulation voltage Ui

500V

Rated current

6A

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

40kA

Rated voltage

240V

Frequency

50 .. 60Hz

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

40kA

Power loss

1.6W

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Current limiting class

3

Flush-mounted installation

Pollution degree

2

Over voltage category

3

Concurrently switching neutral conductor

Width in number of modular spacings

18

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Ambient temperature during operating

-25 .. 60°C

Explosion-proof

Degree of protection (IP)

IP20

Connectable conductor cross section solid-core

0.75 .. 35mm²

Additional equipment possible

From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

We use cookies to enhance your experience.