Aleta.hr
Main Product Image

2CCG000126R0001 | SUP403M-K16

Code: 1999455

ManufacturerRAZNO
Catalog number2CCG000126R0001
Type
EAN code7612271506681

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated insulation voltage Ui

500V

Number of protected poles

3

Rated current

16A

Rated impulse withstand voltage Uimp

4kV

Number of poles (total)

3

Rated voltage

480V

Release characteristic

K

Built-in depth

102mm

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

40kA

Voltage type

Other

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

40kA

Power loss

5.7W

Current limiting class

3

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Frequency

50 - 60Hz

Flush-mounted installation

No

Concurrently switching neutral conductor

No

Over voltage category

3

Pollution degree

2

Additional equipment possible

Yes

Ambient temperature during operating

-25 - 60°C

Degree of protection (IP)

IP20

Connectable conductor cross section solid-core

0.75 - 35mm²

Connectable conductor cross section multi-wired

0.75 - 25mm²

Explosion-proof

No

Width in number of modular spacings

54


Warehouse states

Zagreb:

0 pcs

Zadar:

0 pcs


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

2CCG000126R0001 | SUP403M-K16

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated insulation voltage Ui

500V

Number of protected poles

3

Rated current

16A

Rated impulse withstand voltage Uimp

4kV

Number of poles (total)

3

Rated voltage

480V

Release characteristic

K

Built-in depth

102mm

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

40kA

Voltage type

Other

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

40kA

Power loss

5.7W

Current limiting class

3

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Frequency

50 .. 60Hz

Flush-mounted installation

Concurrently switching neutral conductor

Over voltage category

3

Pollution degree

2

Additional equipment possible

Ambient temperature during operating

-25 .. 60°C

Degree of protection (IP)

IP20

Connectable conductor cross section solid-core

0.75 .. 35mm²

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Explosion-proof

Width in number of modular spacings

54