Aleta.hr
Main Product Image

2CCG000124R0001 | SUP403M-K10

Code: 1999453

ManufacturerRAZNO
Catalog number2CCG000124R0001
Type
EAN code7612271506667

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth

102mm

Number of poles (total)

3

Number of protected poles

3

Release characteristic

K

Rated voltage

480V

Rated insulation voltage Ui

500V

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Rated impulse withstand voltage Uimp

4kV

Power loss

3.9W

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Rated current

10A

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

40kA

Voltage type

Other

Frequency

50 - 60Hz

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

40kA

Current limiting class

3

Degree of protection (IP)

IP20

Ambient temperature during operating

-25 - 60°C

Connectable conductor cross section solid-core

0.75 - 35mm²

Flush-mounted installation

No

Explosion-proof

No

Additional equipment possible

Yes

Width in number of modular spacings

54

Over voltage category

3

Connectable conductor cross section multi-wired

0.75 - 25mm²

Concurrently switching neutral conductor

No

Pollution degree

2


Warehouse states

Zagreb:

0 pcs

Zadar:

0 pcs


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

2CCG000124R0001 | SUP403M-K10

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth

102mm

Number of poles (total)

3

Number of protected poles

3

Release characteristic

K

Rated voltage

480V

Rated insulation voltage Ui

500V

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Rated impulse withstand voltage Uimp

4kV

Power loss

3.9W

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Rated current

10A

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

40kA

Voltage type

Other

Frequency

50 .. 60Hz

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

40kA

Current limiting class

3

Degree of protection (IP)

IP20

Ambient temperature during operating

-25 .. 60°C

Connectable conductor cross section solid-core

0.75 .. 35mm²

Flush-mounted installation

Explosion-proof

Additional equipment possible

Width in number of modular spacings

54

Over voltage category

3

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Concurrently switching neutral conductor

Pollution degree

2

From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.