Aleta.hr
Main Product Image

2CCF019914R0001 | S804S-B1

Code: 1999069

ManufacturerRAZNO
Catalog number2CCF019914R0001
Type
EAN code7612271499808

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Release characteristic

B

Number of protected poles

4

Rated current

1A

Built-in depth

82.5mm

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

25kA

Rated voltage

400V

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Rated impulse withstand voltage Uimp

8kV

Voltage type

Other

Rated insulation voltage Ui

690V

Number of poles (total)

4

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

50kA

Frequency

50 - 60Hz

Current limiting class

3

Power loss

6.4W

Over voltage category

4

Additional equipment possible

Yes

Concurrently switching neutral conductor

Yes

Pollution degree

3

Width in number of modular spacings

6

Connectable conductor cross section multi-wired

0 - 50mm²

Flush-mounted installation

Yes

Explosion-proof

No

Connectable conductor cross section solid-core

0 - 70mm²

Ambient temperature during operating

-25 - 60°C

Degree of protection (IP)

IP20


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

2CCF019914R0001 | S804S-B1

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Release characteristic

B

Number of protected poles

4

Rated current

1A

Built-in depth

82.5mm

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

25kA

Rated voltage

400V

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Rated impulse withstand voltage Uimp

8kV

Voltage type

Other

Rated insulation voltage Ui

690V

Number of poles (total)

4

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

50kA

Frequency

50 .. 60Hz

Current limiting class

3

Power loss

6.4W

Over voltage category

4

Additional equipment possible

Concurrently switching neutral conductor

Pollution degree

3

Width in number of modular spacings

6

Connectable conductor cross section multi-wired

0 .. 50mm²

Flush-mounted installation

Explosion-proof

Connectable conductor cross section solid-core

0 .. 70mm²

Ambient temperature during operating

-25 .. 60°C

Degree of protection (IP)

IP20

From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

We use cookies to enhance your experience.