Aleta.hr
Main Product Image

2CCF019894R0001 | S803S-B3

Code: 1999050

ManufacturerRAZNO
Catalog number2CCF019894R0001
Type
EAN code7612271499600

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated insulation voltage Ui

690V

Built-in depth

82.5mm

Voltage type

Other

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

25kA

Rated voltage

400V

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Number of poles (total)

3

Power loss

7.2W

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Current limiting class

3

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

50kA

Number of protected poles

3

Rated current

3A

Release characteristic

B

Frequency

50 - 60Hz

Rated impulse withstand voltage Uimp

8kV

Over voltage category

4

Connectable conductor cross section solid-core

0 - 70mm²

Pollution degree

3

Width in number of modular spacings

4.5

Flush-mounted installation

Yes

Additional equipment possible

Yes

Connectable conductor cross section multi-wired

0 - 50mm²

Ambient temperature during operating

-25 - 60°C

Concurrently switching neutral conductor

Yes

Degree of protection (IP)

IP20

Explosion-proof

No


Warehouse states

Zagreb:

0 pcs

Zadar:

0 pcs


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

2CCF019894R0001 | S803S-B3

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated insulation voltage Ui

690V

Built-in depth

82.5mm

Voltage type

Other

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

25kA

Rated voltage

400V

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Number of poles (total)

3

Power loss

7.2W

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Current limiting class

3

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

50kA

Number of protected poles

3

Rated current

3A

Release characteristic

B

Frequency

50 .. 60Hz

Rated impulse withstand voltage Uimp

8kV

Over voltage category

4

Connectable conductor cross section solid-core

0 .. 70mm²

Pollution degree

3

Width in number of modular spacings

4.5

Flush-mounted installation

Additional equipment possible

Connectable conductor cross section multi-wired

0 .. 50mm²

Ambient temperature during operating

-25 .. 60°C

Concurrently switching neutral conductor

Degree of protection (IP)

IP20

Explosion-proof

From same serie