Details
- Earthing, lightning and surge protection
- Combined arrester for power supply systems
- 1 KOM
- OBO
Technical specifications
System configuration TN-S
Yes
System configuration DC
No
System configuration TN-C-S
Yes
System configuration TN
Yes
Number of poles
2
System configuration other
No
Nominal voltage AC
120V
Nominal voltage DC
-V
System configuration TN-C
No
System configuration IT
No
Max. continuous voltage DC
-V
Voltage protection level
0.8kV
Voltage protection level L-N
0.8kV
Max. continuous voltage AC
150V
Lightning impulse current (10/350 µs)
12.5kA
System configuration TT
Yes
Max. PV-voltage
-V
Max. overcurrent protection device, parallel connection (fuse)
-A
Follow current extinguishing capability
0.1kA
Voltage protection level L-PE
-kV
Specific energy (W/R)
-kJ/Ohm
Max. overcurrent protection device, series connection (fuse)
-A
Construction size
2 modular spacing
Integrated backup fuse
No
Voltage protection level (DC+ - DC-)
-kV
Remote signalling
No
Voltage protection level N-PE
-kV
Mounting method
DIN rail (top hat rail) 35 mm
Energy-coordinated protection effect with regard to the terminal equipment
No
Max. conductor cross section flexible (fine-strand)
35mm²
Voltage switching spark gap technology
No
Max. conductor cross section solid (solid, stranded)
35mm²
Degree of protection (IP)
IP20
Overcurrent protected voltage tapping
No
Voltage protection level (DC+/DC- - PE)
-kV
Signalling at the device
Optic
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
5093460 | V50-1+NPE+FS-150

Details
- Earthing, lightning and surge protection
- Combined arrester for power supply systems
- 1 KOM
- OBO
Technical specifications
System configuration TN-S
System configuration DC
System configuration TN-C-S
System configuration TN
Number of poles
2
System configuration other
Nominal voltage AC
120V
Nominal voltage DC
-V
System configuration TN-C
System configuration IT
Max. continuous voltage DC
-V
Voltage protection level
0.8kV
Voltage protection level L-N
0.8kV
Max. continuous voltage AC
150V
Lightning impulse current (10/350 µs)
12.5kA
System configuration TT
Max. PV-voltage
-V
Max. overcurrent protection device, parallel connection (fuse)
-A
Follow current extinguishing capability
0.1kA
Voltage protection level L-PE
-kV
Specific energy (W/R)
-kJ/Ohm
Max. overcurrent protection device, series connection (fuse)
-A
Construction size
2 modular spacing
Integrated backup fuse
Voltage protection level (DC+ - DC-)
-kV
Remote signalling
Voltage protection level N-PE
-kV
Mounting method
DIN rail (top hat rail) 35 mm
Energy-coordinated protection effect with regard to the terminal equipment
Max. conductor cross section flexible (fine-strand)
35mm²
Voltage switching spark gap technology
Max. conductor cross section solid (solid, stranded)
35mm²
Degree of protection (IP)
IP20
Overcurrent protected voltage tapping
Voltage protection level (DC+/DC- - PE)
-kV
Signalling at the device
Optic
From same serie