Catalog number2CDS383001R0404
Type
EAN code4016779077804

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth

69mm

Rated current

40A

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

25kA

Release characteristic

C

Voltage type

Other

Frequency

50 - 60Hz

Power loss

8.7W

Number of protected poles

3

Number of poles (total)

3

Rated insulation voltage Ui

500V

Concurrently switching neutral conductor

No

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

20kA

Rated voltage

415V

Over voltage category

4

Rated impulse withstand voltage Uimp

6kV

Flush-mounted installation

No

Current limiting class

-

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Explosion-proof

No

Degree of protection (IP)

IP20

Additional equipment possible

Yes

Width in number of modular spacings

3.0

Connectable conductor cross section solid-core

0.75 - 35mm²

Pollution degree

3

Ambient temperature during operating

-40 - 70°C

Connectable conductor cross section multi-wired

0.75 - 25mm²


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

2CDS383001R0404 | S303P-C40

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth

69mm

Rated current

40A

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

25kA

Release characteristic

C

Voltage type

Other

Frequency

50 .. 60Hz

Power loss

8.7W

Number of protected poles

3

Number of poles (total)

3

Rated insulation voltage Ui

500V

Concurrently switching neutral conductor

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

20kA

Rated voltage

415V

Over voltage category

4

Rated impulse withstand voltage Uimp

6kV

Flush-mounted installation

Current limiting class

-

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Explosion-proof

Degree of protection (IP)

IP20

Additional equipment possible

Width in number of modular spacings

3.0

Connectable conductor cross section solid-core

0.75 .. 35mm²

Pollution degree

3

Ambient temperature during operating

-40 .. 70°C

Connectable conductor cross section multi-wired

0.75 .. 25mm²