Aleta.hr
Main Product Image

2CDS382001R0971 | S302P-D1.6

Code: 1997271

ManufacturerRAZNO
Catalog number2CDS382001R0971
Type
EAN code4016779078337

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Release characteristic

D

Number of poles (total)

2

Rated voltage

415V

Number of protected poles

2

Rated current

1.6A

Built-in depth

69mm

Rated insulation voltage Ui

500V

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

25kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

100kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Rated impulse withstand voltage Uimp

6kV

Current limiting class

-

Power loss

2.6W

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Voltage type

Other

Frequency

50 - 60Hz

Concurrently switching neutral conductor

No

Flush-mounted installation

No

Additional equipment possible

Yes

Pollution degree

3

Explosion-proof

No

Width in number of modular spacings

2.0

Over voltage category

4

Degree of protection (IP)

IP20

Ambient temperature during operating

-40 - 70°C

Connectable conductor cross section multi-wired

0.75 - 25mm²

Connectable conductor cross section solid-core

0.75 - 35mm²


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

2CDS382001R0971 | S302P-D1.6

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Release characteristic

D

Number of poles (total)

2

Rated voltage

415V

Number of protected poles

2

Rated current

1.6A

Built-in depth

69mm

Rated insulation voltage Ui

500V

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

25kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

100kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Rated impulse withstand voltage Uimp

6kV

Current limiting class

-

Power loss

2.6W

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Voltage type

Other

Frequency

50 .. 60Hz

Concurrently switching neutral conductor

Flush-mounted installation

Additional equipment possible

Pollution degree

3

Explosion-proof

Width in number of modular spacings

2.0

Over voltage category

4

Degree of protection (IP)

IP20

Ambient temperature during operating

-40 .. 70°C

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Connectable conductor cross section solid-core

0.75 .. 35mm²

From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.