Aleta.hr
Main Product Image

2CDS382001R0505 | S302P-B50

Code: 1997257

ManufacturerRAZNO
Catalog number2CDS382001R0505
Type
EAN code4016779078474

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Release characteristic

B

Voltage type

Other

Rated impulse withstand voltage Uimp

6kV

Rated voltage

415V

Rated insulation voltage Ui

500V

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

15kA

Frequency

50 - 60Hz

Current limiting class

-

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Power loss

7.4W

Number of poles (total)

2

Number of protected poles

2

Built-in depth

69mm

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Rated current

50A

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

25kA

Concurrently switching neutral conductor

No

Over voltage category

4

Pollution degree

3

Flush-mounted installation

No

Additional equipment possible

Yes

Width in number of modular spacings

2.0

Degree of protection (IP)

IP20

Connectable conductor cross section solid-core

0.75 - 35mm²

Ambient temperature during operating

-40 - 70°C

Explosion-proof

No

Connectable conductor cross section multi-wired

0.75 - 25mm²


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

2CDS382001R0505 | S302P-B50

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Release characteristic

B

Voltage type

Other

Rated impulse withstand voltage Uimp

6kV

Rated voltage

415V

Rated insulation voltage Ui

500V

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

15kA

Frequency

50 .. 60Hz

Current limiting class

-

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Power loss

7.4W

Number of poles (total)

2

Number of protected poles

2

Built-in depth

69mm

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Rated current

50A

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

25kA

Concurrently switching neutral conductor

Over voltage category

4

Pollution degree

3

Flush-mounted installation

Additional equipment possible

Width in number of modular spacings

2.0

Degree of protection (IP)

IP20

Connectable conductor cross section solid-core

0.75 .. 35mm²

Ambient temperature during operating

-40 .. 70°C

Explosion-proof

Connectable conductor cross section multi-wired

0.75 .. 25mm²

From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

We use cookies to enhance your experience.