Catalog number2CDS382001R0278
Type
EAN code4016779078719

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated voltage

415V

Rated current

2A

Number of protected poles

2

Rated insulation voltage Ui

500V

Rated impulse withstand voltage Uimp

6kV

Release characteristic

Z

Number of poles (total)

2

Built-in depth

69mm

Voltage type

Other

Power loss

4.2W

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Frequency

50 - 60Hz

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

100kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

25kA

Current limiting class

-

Additional equipment possible

Yes

Flush-mounted installation

No

Ambient temperature during operating

-40 - 70°C

Over voltage category

4

Pollution degree

3

Width in number of modular spacings

2.0

Concurrently switching neutral conductor

No

Explosion-proof

No

Connectable conductor cross section solid-core

0.75 - 35mm²

Connectable conductor cross section multi-wired

0.75 - 25mm²

Degree of protection (IP)

IP20


Warehouse states

Zagreb:

0 pcs

Zadar:

0 pcs


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

2CDS382001R0278 | S302P-Z2

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated voltage

415V

Rated current

2A

Number of protected poles

2

Rated insulation voltage Ui

500V

Rated impulse withstand voltage Uimp

6kV

Release characteristic

Z

Number of poles (total)

2

Built-in depth

69mm

Voltage type

Other

Power loss

4.2W

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Frequency

50 .. 60Hz

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

100kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

25kA

Current limiting class

-

Additional equipment possible

Flush-mounted installation

Ambient temperature during operating

-40 .. 70°C

Over voltage category

4

Pollution degree

3

Width in number of modular spacings

2.0

Concurrently switching neutral conductor

Explosion-proof

Connectable conductor cross section solid-core

0.75 .. 35mm²

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Degree of protection (IP)

IP20