Aleta.hr
Main Product Image

2CDS381103R0984 | S301P-C0.5NA

Code: 1997198

ManufacturerRAZNO
Catalog number2CDS381103R0984
Type
EAN code4016779079105

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated impulse withstand voltage Uimp

6kV

Rated insulation voltage Ui

500V

Voltage type

Other

Number of protected poles

1

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

25kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Built-in depth

69mm

Number of poles (total)

2

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

100kA

Power loss

2.6W

Current limiting class

-

Frequency

50 - 60Hz

Rated voltage

240V

Rated current

0.5A

Release characteristic

C

Pollution degree

3

Over voltage category

4

Width in number of modular spacings

2.0

Concurrently switching neutral conductor

Yes

Additional equipment possible

Yes

Flush-mounted installation

No

Degree of protection (IP)

IP20

Ambient temperature during operating

-40 - 70°C

Connectable conductor cross section solid-core

0.75 - 35mm²

Connectable conductor cross section multi-wired

0.75 - 25mm²

Explosion-proof

No


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

2CDS381103R0984 | S301P-C0.5NA

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated impulse withstand voltage Uimp

6kV

Rated insulation voltage Ui

500V

Voltage type

Other

Number of protected poles

1

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

25kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Built-in depth

69mm

Number of poles (total)

2

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

100kA

Power loss

2.6W

Current limiting class

-

Frequency

50 .. 60Hz

Rated voltage

240V

Rated current

0.5A

Release characteristic

C

Pollution degree

3

Over voltage category

4

Width in number of modular spacings

2.0

Concurrently switching neutral conductor

Additional equipment possible

Flush-mounted installation

Degree of protection (IP)

IP20

Ambient temperature during operating

-40 .. 70°C

Connectable conductor cross section solid-core

0.75 .. 35mm²

Connectable conductor cross section multi-wired

0.75 .. 25mm²