Aleta.hr
Main Product Image

2CDS381001R0557 | S301P-K40

Code: 1997110

ManufacturerRAZNO
Catalog number2CDS381001R0557
Type
EAN code4016779080019

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth

69mm

Release characteristic

K

Number of protected poles

1

Number of poles (total)

1

Rated voltage

240V

Rated insulation voltage Ui

500V

Rated current

40A

Rated impulse withstand voltage Uimp

6kV

Voltage type

Other

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

25kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

25kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Frequency

50 - 60Hz

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Power loss

3.4W

Current limiting class

-

Width in number of modular spacings

1.0

Flush-mounted installation

No

Over voltage category

4

Concurrently switching neutral conductor

No

Connectable conductor cross section multi-wired

0.75 - 25mm²

Additional equipment possible

Yes

Connectable conductor cross section solid-core

0.75 - 35mm²

Degree of protection (IP)

IP20

Pollution degree

3

Ambient temperature during operating

-40 - 70°C

Explosion-proof

No


Warehouse states

Zagreb:

0 pcs

Zadar:

0 pcs


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

2CDS381001R0557 | S301P-K40

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth

69mm

Release characteristic

K

Number of protected poles

1

Number of poles (total)

1

Rated voltage

240V

Rated insulation voltage Ui

500V

Rated current

40A

Rated impulse withstand voltage Uimp

6kV

Voltage type

Other

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

25kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

25kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Frequency

50 .. 60Hz

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Power loss

3.4W

Current limiting class

-

Width in number of modular spacings

1.0

Flush-mounted installation

Over voltage category

4

Concurrently switching neutral conductor

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Additional equipment possible

Connectable conductor cross section solid-core

0.75 .. 35mm²

Degree of protection (IP)

IP20

Pollution degree

3

Ambient temperature during operating

-40 .. 70°C