Aleta.hr
Main Product Image

2CCG001302R0001 | S803P-B125-R

Code: 1996998

ManufacturerRAZNO
Catalog number2CCG001302R0001
Type
EAN code7612271517717

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated voltage

400V

Number of poles (total)

3

Rated current

125A

Number of protected poles

3

Built-in depth

82.5mm

Voltage type

Other

Release characteristic

B

Rated impulse withstand voltage Uimp

6kV

Rated insulation voltage Ui

690V

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

15kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Frequency

50 - 60Hz

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

50kA

Current limiting class

3

Power loss

28.2W

Concurrently switching neutral conductor

No

Explosion-proof

No

Pollution degree

3

Width in number of modular spacings

5

Connectable conductor cross section multi-wired

1 - 50mm²

Over voltage category

3

Ambient temperature during operating

-25 - 60°C

Flush-mounted installation

No

Additional equipment possible

Yes

Degree of protection (IP)

IP20

Connectable conductor cross section solid-core

1 - 70mm²


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

2CCG001302R0001 | S803P-B125-R

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated voltage

400V

Number of poles (total)

3

Rated current

125A

Number of protected poles

3

Built-in depth

82.5mm

Voltage type

Other

Release characteristic

B

Rated impulse withstand voltage Uimp

6kV

Rated insulation voltage Ui

690V

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

15kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Frequency

50 .. 60Hz

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

50kA

Current limiting class

3

Power loss

28.2W

Concurrently switching neutral conductor

Explosion-proof

Pollution degree

3

Width in number of modular spacings

5

Connectable conductor cross section multi-wired

1 .. 50mm²

Over voltage category

3

Ambient temperature during operating

-25 .. 60°C

Flush-mounted installation

Additional equipment possible

Degree of protection (IP)

IP20

Connectable conductor cross section solid-core

1 .. 70mm²

From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

We use cookies to enhance your experience.