Aleta.hr
Main Product Image

2CCG001290R0001 | S804P-B100-R

Code: 1996986

ManufacturerRAZNO
Catalog number2CCG001290R0001
Type
EAN code7612271517595

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Release characteristic

B

Rated impulse withstand voltage Uimp

6kV

Rated voltage

400V

Built-in depth

82.5mm

Rated current

100A

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Voltage type

Other

Number of protected poles

4

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

15kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

50kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Rated insulation voltage Ui

690V

Power loss

32W

Current limiting class

3

Frequency

50 - 60Hz

Number of poles (total)

4

Flush-mounted installation

No

Pollution degree

3

Connectable conductor cross section solid-core

1 - 70mm²

Additional equipment possible

Yes

Connectable conductor cross section multi-wired

1 - 50mm²

Over voltage category

3

Explosion-proof

No

Degree of protection (IP)

IP20

Width in number of modular spacings

6

Ambient temperature during operating

-25 - 60°C

Concurrently switching neutral conductor

No


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

2CCG001290R0001 | S804P-B100-R

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Release characteristic

B

Rated impulse withstand voltage Uimp

6kV

Rated voltage

400V

Built-in depth

82.5mm

Rated current

100A

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Voltage type

Other

Number of protected poles

4

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

15kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

50kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Rated insulation voltage Ui

690V

Power loss

32W

Current limiting class

3

Frequency

50 .. 60Hz

Number of poles (total)

4

Flush-mounted installation

Pollution degree

3

Connectable conductor cross section solid-core

1 .. 70mm²

Additional equipment possible

Connectable conductor cross section multi-wired

1 .. 50mm²

Over voltage category

3

Explosion-proof

Degree of protection (IP)

IP20

Width in number of modular spacings

6

Ambient temperature during operating

-25 .. 60°C

Concurrently switching neutral conductor

From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

We use cookies to enhance your experience.