Aleta.hr
Main Product Image

2CCG001238R0001 | S801P-D80

Code: 1996934

ManufacturerRAZNO
Catalog number2CCG001238R0001
Type
EAN code7612271517076

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Number of protected poles

1

Release characteristic

D

Built-in depth

82.5mm

Rated voltage

230V

Number of poles (total)

1

Rated current

80A

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

25kA

Rated insulation voltage Ui

690V

Rated impulse withstand voltage Uimp

6kV

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

25kA

Voltage type

Other

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

50kA

Frequency

50 - 60Hz

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

6kA

Power loss

6.4W

Current limiting class

3

Additional equipment possible

Yes

Over voltage category

3

Degree of protection (IP)

IP20

Width in number of modular spacings

1.5

Pollution degree

3

Flush-mounted installation

No

Connectable conductor cross section solid-core

1 - 70mm²

Ambient temperature during operating

-25 - 60°C

Concurrently switching neutral conductor

No

Explosion-proof

No

Connectable conductor cross section multi-wired

1 - 50mm²


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

2CCG001238R0001 | S801P-D80

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Number of protected poles

1

Release characteristic

D

Built-in depth

82.5mm

Rated voltage

230V

Number of poles (total)

1

Rated current

80A

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

25kA

Rated insulation voltage Ui

690V

Rated impulse withstand voltage Uimp

6kV

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

25kA

Voltage type

Other

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

50kA

Frequency

50 .. 60Hz

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

6kA

Power loss

6.4W

Current limiting class

3

Additional equipment possible

Over voltage category

3

Degree of protection (IP)

IP20

Width in number of modular spacings

1.5

Pollution degree

3

Flush-mounted installation

Connectable conductor cross section solid-core

1 .. 70mm²

Ambient temperature during operating

-25 .. 60°C

Concurrently switching neutral conductor

Explosion-proof

Connectable conductor cross section multi-wired

1 .. 50mm²

From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

We use cookies to enhance your experience.