2CCG001231R0001 | S802P-C125

Code: 1996929

ManufacturerRAZNO
Catalog number2CCG001231R0001
Type
EAN code7612271517007

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Voltage type

Other

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

50kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

30kA

Number of poles (total)

2

Rated voltage

400V

Rated current

125A

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

15kA

Release characteristic

C

Rated insulation voltage Ui

690V

Number of protected poles

2

Rated impulse withstand voltage Uimp

6kV

Built-in depth

82.5mm

Frequency

50 - 60Hz

Current limiting class

3

Power loss

18.8W

Flush-mounted installation

No

Over voltage category

3

Pollution degree

3

Concurrently switching neutral conductor

No

Additional equipment possible

Yes

Ambient temperature during operating

-25 - 60°C

Width in number of modular spacings

3.5

Degree of protection (IP)

IP20

Explosion-proof

No

Connectable conductor cross section multi-wired

1 - 50mm²

Connectable conductor cross section solid-core

1 - 70mm²


Warehouse states

Zagreb:

0 pcs

Zadar:

0 pcs


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

2CCG001231R0001 | S802P-C125

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Voltage type

Other

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

50kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

30kA

Number of poles (total)

2

Rated voltage

400V

Rated current

125A

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

15kA

Release characteristic

C

Rated insulation voltage Ui

690V

Number of protected poles

2

Rated impulse withstand voltage Uimp

6kV

Built-in depth

82.5mm

Frequency

50 .. 60Hz

Current limiting class

3

Power loss

18.8W

Flush-mounted installation

Over voltage category

3

Pollution degree

3

Concurrently switching neutral conductor

Additional equipment possible

Ambient temperature during operating

-25 .. 60°C

Width in number of modular spacings

3.5

Degree of protection (IP)

IP20

Explosion-proof

Connectable conductor cross section multi-wired

1 .. 50mm²

Connectable conductor cross section solid-core

1 .. 70mm²