2CCG001228R0001 | S801P-C125

Code: 1996926

ManufacturerRAZNO
Catalog number2CCG001228R0001
Type
EAN code7612271516970

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth

82.5mm

Number of protected poles

1

Rated voltage

230V

Release characteristic

C

Frequency

50 - 60Hz

Rated impulse withstand voltage Uimp

6kV

Number of poles (total)

1

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

15kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

4.5kA

Voltage type

Other

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

50kA

Power loss

9.4W

Rated insulation voltage Ui

690V

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

15kA

Current limiting class

3

Rated current

125A

Flush-mounted installation

No

Concurrently switching neutral conductor

No

Over voltage category

3

Additional equipment possible

Yes

Pollution degree

3

Explosion-proof

No

Connectable conductor cross section multi-wired

1 - 50mm²

Degree of protection (IP)

IP20

Connectable conductor cross section solid-core

1 - 70mm²

Width in number of modular spacings

1.5

Ambient temperature during operating

-25 - 60°C


Warehouse states

Zagreb:

0 pcs

Zadar:

0 pcs


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

2CCG001228R0001 | S801P-C125

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth

82.5mm

Number of protected poles

1

Rated voltage

230V

Release characteristic

C

Frequency

50 .. 60Hz

Rated impulse withstand voltage Uimp

6kV

Number of poles (total)

1

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

15kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

4.5kA

Voltage type

Other

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

50kA

Power loss

9.4W

Rated insulation voltage Ui

690V

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

15kA

Current limiting class

3

Rated current

125A

Flush-mounted installation

Concurrently switching neutral conductor

Over voltage category

3

Additional equipment possible

Pollution degree

3

Explosion-proof

Connectable conductor cross section multi-wired

1 .. 50mm²

Degree of protection (IP)

IP20

Connectable conductor cross section solid-core

1 .. 70mm²

Width in number of modular spacings

1.5

Ambient temperature during operating

-25 .. 60°C