Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
-kA
With integrated under voltage release
No
Adjustment range undelayed short-circuit release
4800.0 - 48000A
Rated permanent current Iu
3200A
Adjustment range short-term delayed short-circuit release
1920.0 - 32000A
Integrated earth fault protection
No
DIN rail (top hat rail) mounting optional
No
Number of auxiliary contacts as change-over contact
4
Number of poles
4
Rated voltage
730 - 730V
Device construction
Built-in device slide-in technique (withdrawable)
Number of auxiliary contacts as normally closed contact
0
Degree of protection (IP)
IP30
Number of auxiliary contacts as normally open contact
0
Type of control element
Push button
Type of electrical connection of main circuit
Connection at separate chassis part
Motor drive optional
Yes
With switched-off indicator
Yes
Motor drive integrated
No
Overload release current setting
1280.0 - 3200A
Complete device with protection unit
Yes
Suitable for DIN rail (top hat rail) mounting
No
Position of connection for main current circuit
Connection at separate chassis part
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
1SDA113770R1 | E4.2H-A/E 3200 Ekip Dip LSI 4p WMP

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
-kA
With integrated under voltage release
Adjustment range undelayed short-circuit release
4800.0 .. 48000A
Rated permanent current Iu
3200A
Adjustment range short-term delayed short-circuit release
1920.0 .. 32000A
Integrated earth fault protection
DIN rail (top hat rail) mounting optional
Number of auxiliary contacts as change-over contact
4
Number of poles
4
Rated voltage
730 .. 730V
Device construction
Built-in device slide-in technique (withdrawable)
Number of auxiliary contacts as normally closed contact
0
Degree of protection (IP)
IP30
Number of auxiliary contacts as normally open contact
0
Type of control element
Push button
Type of electrical connection of main circuit
Connection at separate chassis part
Motor drive optional
With switched-off indicator
Motor drive integrated
Overload release current setting
1280.0 .. 3200A
Complete device with protection unit
Suitable for DIN rail (top hat rail) mounting
Position of connection for main current circuit
Connection at separate chassis part
From same serie