Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
-kA
With integrated under voltage release
No
Rated voltage
900 - 900V
Rated permanent current Iu
4000A
Adjustment range short-term delayed short-circuit release
2400.0 - 40000A
Type of electrical connection of main circuit
Connection at separate chassis part
Device construction
Built-in device slide-in technique (withdrawable)
Position of connection for main current circuit
Connection at separate chassis part
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
DIN rail (top hat rail) mounting optional
No
Suitable for DIN rail (top hat rail) mounting
No
Complete device with protection unit
Yes
Motor drive integrated
No
Number of auxiliary contacts as change-over contact
4
Type of control element
Push button
Number of poles
4
Degree of protection (IP)
IP30
Motor drive optional
Yes
Integrated earth fault protection
No
Adjustment range undelayed short-circuit release
6000.0 - 60000A
With switched-off indicator
Yes
Overload release current setting
1600.0 - 4000A
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
1SDA104536R1 | E4.2H/E9 4000 Ekip Touch LSI 4p WMP 900V

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
-kA
With integrated under voltage release
Rated voltage
900 .. 900V
Rated permanent current Iu
4000A
Adjustment range short-term delayed short-circuit release
2400.0 .. 40000A
Type of electrical connection of main circuit
Connection at separate chassis part
Device construction
Built-in device slide-in technique (withdrawable)
Position of connection for main current circuit
Connection at separate chassis part
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
DIN rail (top hat rail) mounting optional
Suitable for DIN rail (top hat rail) mounting
Complete device with protection unit
Motor drive integrated
Number of auxiliary contacts as change-over contact
4
Type of control element
Push button
Number of poles
4
Degree of protection (IP)
IP30
Motor drive optional
Integrated earth fault protection
Adjustment range undelayed short-circuit release
6000.0 .. 60000A
With switched-off indicator
Overload release current setting
1600.0 .. 4000A
From same serie