Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
-kA
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Overload release current setting
1600.0 - 4000A
Rated permanent current Iu
4000A
Rated voltage
900 - 900V
Suitable for DIN rail (top hat rail) mounting
No
Adjustment range undelayed short-circuit release
6000.0 - 60000A
DIN rail (top hat rail) mounting optional
No
Number of auxiliary contacts as change-over contact
4
With under voltage release
No
Position of connection for main current circuit
Connection at separate chassis part
Device construction
Built-in device slide-in technique (withdrawable)
With switched-off indicator
Yes
Motor drive integrated
No
Complete device with protection unit
Yes
Type of control element
Push button
Number of poles
3
Adjustment range short-term delayed short-circuit release
2400.0 - 40000A
Degree of protection (IP)
IP30
Motor drive optional
Yes
Type of electrical connection of main circuit
Connection at separate chassis part
Integrated earth fault protection
Yes
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
1SDA104523R1 | E4.2H/E9 4000 Ekip Dip LSIG 3p WMP 900V

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
-kA
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Overload release current setting
1600.0 .. 4000A
Rated permanent current Iu
4000A
Rated voltage
900 .. 900V
Suitable for DIN rail (top hat rail) mounting
Adjustment range undelayed short-circuit release
6000.0 .. 60000A
DIN rail (top hat rail) mounting optional
Number of auxiliary contacts as change-over contact
4
With under voltage release
Position of connection for main current circuit
Connection at separate chassis part
Device construction
Built-in device slide-in technique (withdrawable)
With switched-off indicator
Motor drive integrated
Complete device with protection unit
Type of control element
Push button
Number of poles
3
Adjustment range short-term delayed short-circuit release
2400.0 .. 40000A
Degree of protection (IP)
IP30
Motor drive optional
Type of electrical connection of main circuit
Connection at separate chassis part
Integrated earth fault protection
From same serie