Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
-kA
With integrated under voltage release
No
Overload release current setting
1280.0 - 3200A
Type of electrical connection of main circuit
Connection at separate chassis part
Adjustment range undelayed short-circuit release
4800.0 - 48000A
Suitable for DIN rail (top hat rail) mounting
No
Integrated earth fault protection
Yes
Adjustment range short-term delayed short-circuit release
1920.0 - 32000A
Rated permanent current Iu
3200A
Number of auxiliary contacts as normally closed contact
0
Number of poles
3
Number of auxiliary contacts as change-over contact
4
DIN rail (top hat rail) mounting optional
No
Motor drive integrated
No
Device construction
Built-in device slide-in technique (withdrawable)
Number of auxiliary contacts as normally open contact
0
Motor drive optional
Yes
Degree of protection (IP)
IP30
Position of connection for main current circuit
Connection at separate chassis part
With switched-off indicator
Yes
Rated voltage
900 - 900V
Type of control element
Push button
Complete device with protection unit
Yes
From same serie
1SDA104520R1 | E4.2H/E9 3200 EkipHi-Tch LSIG 3pWMP 900V

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
-kA
With integrated under voltage release
Overload release current setting
1280.0 .. 3200A
Type of electrical connection of main circuit
Connection at separate chassis part
Adjustment range undelayed short-circuit release
4800.0 .. 48000A
Suitable for DIN rail (top hat rail) mounting
Integrated earth fault protection
Adjustment range short-term delayed short-circuit release
1920.0 .. 32000A
Rated permanent current Iu
3200A
Number of auxiliary contacts as normally closed contact
0
Number of poles
3
Number of auxiliary contacts as change-over contact
4
DIN rail (top hat rail) mounting optional
Motor drive integrated
Device construction
Built-in device slide-in technique (withdrawable)
Number of auxiliary contacts as normally open contact
0
Motor drive optional
Degree of protection (IP)
IP30
Position of connection for main current circuit
Connection at separate chassis part
With switched-off indicator
Rated voltage
900 .. 900V
Type of control element
Push button
Complete device with protection unit
From same serie
We use cookies to enhance your experience.