Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
-kA
With integrated under voltage release
No
Rated permanent current Iu
2500A
Integrated earth fault protection
Yes
Overload release current setting
1000.0 - 2500A
Number of auxiliary contacts as change-over contact
4
Device construction
Built-in device slide-in technique (withdrawable)
Number of auxiliary contacts as normally closed contact
0
Adjustment range undelayed short-circuit release
3750.0 - 37500A
Number of poles
4
Number of auxiliary contacts as normally open contact
0
Position of connection for main current circuit
Connection at separate chassis part
Rated voltage
900 - 900V
With switched-off indicator
Yes
Complete device with protection unit
Yes
Adjustment range short-term delayed short-circuit release
1500.0 - 25000A
Suitable for DIN rail (top hat rail) mounting
No
Type of electrical connection of main circuit
Connection at separate chassis part
Motor drive optional
Yes
Motor drive integrated
No
Degree of protection (IP)
IP30
DIN rail (top hat rail) mounting optional
No
Type of control element
Push button
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
1SDA104493R1 | E2.2H/E9 2500 Ekip Dip LSIG 4p WMP 900V

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
-kA
With integrated under voltage release
Rated permanent current Iu
2500A
Integrated earth fault protection
Overload release current setting
1000.0 .. 2500A
Number of auxiliary contacts as change-over contact
4
Device construction
Built-in device slide-in technique (withdrawable)
Number of auxiliary contacts as normally closed contact
0
Adjustment range undelayed short-circuit release
3750.0 .. 37500A
Number of poles
4
Number of auxiliary contacts as normally open contact
0
Position of connection for main current circuit
Connection at separate chassis part
Rated voltage
900 .. 900V
With switched-off indicator
Complete device with protection unit
Adjustment range short-term delayed short-circuit release
1500.0 .. 25000A
Suitable for DIN rail (top hat rail) mounting
Type of electrical connection of main circuit
Connection at separate chassis part
Motor drive optional
Motor drive integrated
Degree of protection (IP)
IP30
DIN rail (top hat rail) mounting optional
Type of control element
Push button
From same serie