Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
-kA
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Type of electrical connection of main circuit
Connection at separate chassis part
Overload release current setting
1000.0 - 2500A
Type of control element
Push button
Rated voltage
900 - 900V
Degree of protection (IP)
IP30
Motor drive integrated
No
Rated permanent current Iu
2500A
Position of connection for main current circuit
Connection at separate chassis part
Integrated earth fault protection
Yes
Adjustment range undelayed short-circuit release
3750.0 - 37500A
Adjustment range short-term delayed short-circuit release
1500.0 - 25000A
DIN rail (top hat rail) mounting optional
No
With under voltage release
No
Suitable for DIN rail (top hat rail) mounting
No
With switched-off indicator
Yes
Device construction
Built-in device slide-in technique (withdrawable)
Motor drive optional
Yes
Complete device with protection unit
Yes
Number of poles
4
Number of auxiliary contacts as change-over contact
4
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
1SDA104465R1 | E2.2S/E9 2500 EkipHi-Tch LSIG 4pWMP 900V

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
-kA
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Type of electrical connection of main circuit
Connection at separate chassis part
Overload release current setting
1000.0 .. 2500A
Type of control element
Push button
Rated voltage
900 .. 900V
Degree of protection (IP)
IP30
Motor drive integrated
Rated permanent current Iu
2500A
Position of connection for main current circuit
Connection at separate chassis part
Integrated earth fault protection
Adjustment range undelayed short-circuit release
3750.0 .. 37500A
Adjustment range short-term delayed short-circuit release
1500.0 .. 25000A
DIN rail (top hat rail) mounting optional
With under voltage release
Suitable for DIN rail (top hat rail) mounting
With switched-off indicator
Device construction
Built-in device slide-in technique (withdrawable)
Motor drive optional
Complete device with protection unit
Number of poles
4
Number of auxiliary contacts as change-over contact
4
From same serie