Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
-kA
With integrated under voltage release
No
Overload release current setting
500.0 - 1250A
Number of auxiliary contacts as normally closed contact
0
Integrated earth fault protection
Yes
Rated voltage
900 - 900V
DIN rail (top hat rail) mounting optional
No
Number of poles
3
Rated permanent current Iu
1250A
Position of connection for main current circuit
Connection at separate chassis part
Adjustment range short-term delayed short-circuit release
750.0 - 12500A
Complete device with protection unit
Yes
With switched-off indicator
Yes
Device construction
Built-in device slide-in technique (withdrawable)
Adjustment range undelayed short-circuit release
1875.0 - 18750A
Type of electrical connection of main circuit
Connection at separate chassis part
Suitable for DIN rail (top hat rail) mounting
No
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as change-over contact
4
Motor drive optional
Yes
Motor drive integrated
No
Type of control element
Push button
Degree of protection (IP)
IP30
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
1SDA104440R1 | E2.2S/E9 1250 EkipHi-Tch LSIG 3pWMP 900V

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
-kA
With integrated under voltage release
Overload release current setting
500.0 .. 1250A
Number of auxiliary contacts as normally closed contact
0
Integrated earth fault protection
Rated voltage
900 .. 900V
DIN rail (top hat rail) mounting optional
Number of poles
3
Rated permanent current Iu
1250A
Position of connection for main current circuit
Connection at separate chassis part
Adjustment range short-term delayed short-circuit release
750.0 .. 12500A
Complete device with protection unit
With switched-off indicator
Device construction
Built-in device slide-in technique (withdrawable)
Adjustment range undelayed short-circuit release
1875.0 .. 18750A
Type of electrical connection of main circuit
Connection at separate chassis part
Suitable for DIN rail (top hat rail) mounting
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as change-over contact
4
Motor drive optional
Motor drive integrated
Type of control element
Push button
Degree of protection (IP)
IP30
From same serie