Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
-kA
With integrated under voltage release
No
Rated permanent current Iu
3200A
Rated voltage
900 - 900V
Adjustment range short-term delayed short-circuit release
1920.0 - 32000A
Number of poles
3
Suitable for DIN rail (top hat rail) mounting
No
DIN rail (top hat rail) mounting optional
No
Adjustment range undelayed short-circuit release
4800.0 - 48000A
Motor drive optional
Yes
Complete device with protection unit
Yes
Device construction
Built-in device fixed built-in technique
Overload release current setting
1280.0 - 3200A
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as change-over contact
4
Type of electrical connection of main circuit
Bolt connection
With switched-off indicator
Yes
Motor drive integrated
No
Type of control element
Push button
Degree of protection (IP)
IP30
Integrated earth fault protection
Yes
Position of connection for main current circuit
Back side
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
1SDA104400R1 | E4.2H/E9 3200 Ekip Hi-Touch LSIG 3p FHR

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
-kA
With integrated under voltage release
Rated permanent current Iu
3200A
Rated voltage
900 .. 900V
Adjustment range short-term delayed short-circuit release
1920.0 .. 32000A
Number of poles
3
Suitable for DIN rail (top hat rail) mounting
DIN rail (top hat rail) mounting optional
Adjustment range undelayed short-circuit release
4800.0 .. 48000A
Motor drive optional
Complete device with protection unit
Device construction
Built-in device fixed built-in technique
Overload release current setting
1280.0 .. 3200A
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as change-over contact
4
Type of electrical connection of main circuit
Bolt connection
With switched-off indicator
Motor drive integrated
Type of control element
Push button
Degree of protection (IP)
IP30
Integrated earth fault protection
Position of connection for main current circuit
Back side