Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
-kA
With integrated under voltage release
No
Rated permanent current Iu
1250A
Integrated earth fault protection
No
Type of electrical connection of main circuit
Connection at separate chassis part
Adjustment range undelayed short-circuit release
1875.0 - 18750A
Number of auxiliary contacts as change-over contact
4
DIN rail (top hat rail) mounting optional
No
Rated voltage
800 - 800V
Device construction
Built-in device slide-in technique (withdrawable)
Number of auxiliary contacts as normally closed contact
0
Degree of protection (IP)
IP30
Number of auxiliary contacts as normally open contact
0
Overload release current setting
500.0 - 1250A
Adjustment range short-term delayed short-circuit release
750.0 - 12500A
Type of control element
Push button
Suitable for DIN rail (top hat rail) mounting
No
Motor drive integrated
No
Number of poles
4
With switched-off indicator
Yes
Position of connection for main current circuit
Connection at separate chassis part
Motor drive optional
Yes
Complete device with protection unit
Yes
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
1SDA104308R1 | E1.2N/E9 1250 Ekip Touch LSI 4p WMP

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
-kA
With integrated under voltage release
Rated permanent current Iu
1250A
Integrated earth fault protection
Type of electrical connection of main circuit
Connection at separate chassis part
Adjustment range undelayed short-circuit release
1875.0 .. 18750A
Number of auxiliary contacts as change-over contact
4
DIN rail (top hat rail) mounting optional
Rated voltage
800 .. 800V
Device construction
Built-in device slide-in technique (withdrawable)
Number of auxiliary contacts as normally closed contact
0
Degree of protection (IP)
IP30
Number of auxiliary contacts as normally open contact
0
Overload release current setting
500.0 .. 1250A
Adjustment range short-term delayed short-circuit release
750.0 .. 12500A
Type of control element
Push button
Suitable for DIN rail (top hat rail) mounting
Motor drive integrated
Number of poles
4
With switched-off indicator
Position of connection for main current circuit
Connection at separate chassis part
Motor drive optional
Complete device with protection unit
From same serie
We use cookies to enhance your experience.