Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Rated voltage
240 - 600V
Overload release current setting
100.0 - 250A
Adjustment range undelayed short-circuit release
250 - 2500A
Rated permanent current Iu
250A
DIN rail (top hat rail) mounting optional
Yes
Adjustment range short-term delayed short-circuit release
250 - 2500A
Device construction
Built-in device fixed built-in technique
Integrated earth fault protection
No
Number of auxiliary contacts as change-over contact
0
With integrated under voltage release
No
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as normally closed contact
0
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
150kA
Type of electrical connection of main circuit
Bolt connection
Motor drive integrated
No
Degree of protection (IP)
IP20
Motor drive optional
Yes
With switched-off indicator
No
Number of poles
3
Type of control element
Toggle
Complete device with protection unit
Yes
Position of connection for main current circuit
Front side
Suitable for DIN rail (top hat rail) mounting
No
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
1SDA080283R1 | XT4V 250 EKIP E-LSIG In250A 3p FF UL/CSA

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Rated voltage
240 .. 600V
Overload release current setting
100.0 .. 250A
Adjustment range undelayed short-circuit release
250 .. 2500A
Rated permanent current Iu
250A
DIN rail (top hat rail) mounting optional
Adjustment range short-term delayed short-circuit release
250 .. 2500A
Device construction
Built-in device fixed built-in technique
Integrated earth fault protection
Number of auxiliary contacts as change-over contact
0
With integrated under voltage release
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as normally closed contact
0
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
150kA
Type of electrical connection of main circuit
Bolt connection
Motor drive integrated
Degree of protection (IP)
IP20
Motor drive optional
With switched-off indicator
Number of poles
3
Type of control element
Toggle
Complete device with protection unit
Position of connection for main current circuit
Front side
Suitable for DIN rail (top hat rail) mounting
From same serie
We use cookies to enhance your experience.