Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Rated permanent current Iu
250A
Rated voltage
240 - 600V
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
150kA
Adjustment range undelayed short-circuit release
100 - 1000A
Adjustment range short-term delayed short-circuit release
100 - 1000A
Integrated earth fault protection
No
Overload release current setting
40.0 - 100A
Type of electrical connection of main circuit
Bolt connection
Device construction
Built-in device fixed built-in technique
Suitable for DIN rail (top hat rail) mounting
No
DIN rail (top hat rail) mounting optional
Yes
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as change-over contact
0
With integrated under voltage release
No
With switched-off indicator
No
Position of connection for main current circuit
Front side
Type of control element
Toggle
Motor drive integrated
No
Degree of protection (IP)
IP20
Complete device with protection unit
Yes
Number of poles
4
Motor drive optional
Yes
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
1SDA080278R1 | XT4V 250 EKIP E-LSIG In100A 4p FF UL/CSA

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Rated permanent current Iu
250A
Rated voltage
240 .. 600V
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
150kA
Adjustment range undelayed short-circuit release
100 .. 1000A
Adjustment range short-term delayed short-circuit release
100 .. 1000A
Integrated earth fault protection
Overload release current setting
40.0 .. 100A
Type of electrical connection of main circuit
Bolt connection
Device construction
Built-in device fixed built-in technique
Suitable for DIN rail (top hat rail) mounting
DIN rail (top hat rail) mounting optional
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as change-over contact
0
With integrated under voltage release
With switched-off indicator
Position of connection for main current circuit
Front side
Type of control element
Toggle
Motor drive integrated
Degree of protection (IP)
IP20
Complete device with protection unit
Number of poles
4
Motor drive optional
From same serie